BENERU
Law, contracts and systemsPublished

Energy efficiency standards became mandatory in 2025. Do I have to bring my existing old apartment building up to the standards too?

BENERU writes for readers who live in Japan. Taxes, loans and the other rules described here are those of Japan, and they assume a resident of Japan.
This page is a translation of the Japanese original. If the two differ, the Japanese original prevails.

2 people have answered. Each answerer sees it differently.

Ritsu SakakibaraFinancial product examiner

This is Ritsu Sakakibara. I will give the conclusion first.

The obligation to conform to the energy efficiency standards that began in April 2025 is an obligation placed on the building owner (kenchikunushi) when a building is newly built, extended or reconstructed. Simply continuing to use, rent out or sell an existing apartment building does not trigger this obligation. There is also no provision requiring an existing building that does not meet the standards to be renovated to meet them. If you extend or reconstruct, the part being extended or reconstructed must conform to the standards.

What is decided, and how

The basis is the Act on the Improvement of Energy Consumption Performance of Buildings (Act No. 53 of 2015 (Heisei 27), commonly called the Building Energy Efficiency Act).

  1. When a building owner intends to construct a building (excluding those at or below a size set by Cabinet Order), the owner must make that building conform to the building energy consumption performance standards (commonly called the energy efficiency standards). In the case of an extension or reconstruction, the part being extended or reconstructed is covered (Act Article 10, paragraph 1).
  2. This provision is deemed a building standards-related provision and is examined in building confirmation (kenchiku kakunin) (Act Article 10, paragraph 2).
  3. The excluded size is set by Cabinet Order as a floor area of 10㎡ or less.
  4. Through the amendment by Act No. 69 of 2022 (Reiwa 4), it applies to buildings whose construction started in or after April 2025 (Reiwa 7). Construction starts at the point when piling, ground improvement, earth retaining or excavation work begins. Until then, the obligation to conform covered medium- and large-scale (floor area of 300㎡ or more) non-residential buildings.

What to compare

ActionObligation to conform to the energy efficiency standardsBasis
Continuing to use, renting out or selling the current buildingDoes not applyAct Article 10, paragraph 1 (an obligation when intending to construct)
Repair or remodeling (including major repair and major remodeling)Does not applyMLIT Q&A collection 1-2 Q1 and Q2
Only replacing equipment such as air conditioning (where it does not count as new construction, extension or reconstruction)Does not applySame, 1-1 Q19
Change of use (where it does not count as new construction, extension or reconstruction)Does not applySame, 1-1 Q20
Extension or reconstruction (floor area of the extended or reconstructed part over 10㎡)The part being extended or reconstructed must conformAct Article 10, paragraph 1; same, 1-2 Q3 (shown as the case where the whole building after the extension or reconstruction falls under Building Standards Act Article 6, paragraph 1, items 1 and 2)
Rebuilding (new construction)The whole building must conformAct Article 10, paragraph 1

Even if repair or remodeling is outside the energy efficiency standards, that does not mean building confirmation is not required. After the revision of the Building Standards Act in force from April 2025, buildings with two or more stories or with a total floor area over 200㎡ are subject to building confirmation and inspection even for major repair or major remodeling (same, Building Standards Act section 2 Q1). A 2-story wooden apartment building falls under this. Apartment buildings where the floor area used for that purpose exceeds 200㎡ were covered before the revision, and what the revision newly brought in is mainly smaller wooden buildings. This is an easily overlooked point.

Where the answer splits

Whether the obligation applies is decided by the following 3 points.

  1. Whether the work counts as new construction, extension or reconstruction (if it is only repair, remodeling, equipment replacement or change of use, it does not)
  2. For an extension or reconstruction, whether the floor area of that part exceeds 10㎡
  3. Whether construction started in or after April 2025 (Reiwa 7)

The following is an assumption for illustration. Take a 2-story wooden apartment building with a total floor area of 240㎡.

WorkScope that must conform to the energy efficiency standards
Renovating the outer walls or roof (repair or remodeling)None (check separately whether building confirmation is required)
Adding a 30㎡ unit on the 1st floorThe 30㎡ part being added
Demolishing and building newThe whole new building

Labeling when renting out or selling

The system for showing energy efficiency performance in sales and rental advertising (the energy efficiency performance labeling system for the sale and rental of buildings) is a duty to make efforts for sellers and lessors in the business. It covers buildings for which building confirmation was applied for in or after April 2024 (Reiwa 6). For existing buildings for which confirmation was applied for before that, and whose energy efficiency performance is hard to determine, labeling in the form set by the notice is not uniformly required. Where the performance is known, labeling in the form set by the notice is said to be desirable (same, labeling system Q4 and Q12). MLIT recommends labeling existing buildings too, but says not labeling does not make one subject to a recommendation or the like. For existing housing, an "energy efficiency component label," which shows the components that have had energy efficiency renovations such as windows and water heaters, has been in use since November 2024.

Conditions behind the numbers

  • This is based on the laws and regulations as of November 2026 and MLIT's Q&A collection (as of November 2, 2026 (Reiwa 8)).
  • The Act has a provision that building owners and others shall also endeavor to improve energy efficiency performance (Act Article 6, paragraph 2), and the national basic policy (MLIT Notice No. 971 of 2023 (Reiwa 5)) sets out the measures owners and others should take. It is a duty-to-make-efforts provision, not a provision ordering renovation.
  • Whether an extension or reconstruction requires the energy efficiency conformity assessment procedure also depends on the size of the building after the extension or reconstruction. Individual cases are judged by the designated administrative agency or a designated confirmation and inspection body.

Order of checks

  1. Write down whether your plan for the next 10 years or so includes an extension or rebuilding.
  2. Sort the planned work into new construction, extension or reconstruction versus repair or remodeling.
  3. For an extension, check the floor area of the added part and the planned construction start date.
  4. Even for repair or remodeling, check from the building's number of stories and total floor area whether building confirmation is required.
  5. If you plan to rent out or sell, gather the specifications you know, such as windows and water heaters, and the records of renovations.

From here on, this is my opinion

For existing apartment buildings, I do not think there is any need to rush into energy efficiency renovations on the grounds of the conformity obligation. It is reasonable to decide whether to renovate by whether the effect on utility costs and on how easily units are let justifies the cost. On the other hand, if your plan includes rebuilding or an extension, I think the cost estimate should include the amount needed to conform to the standards.

RitaSharp-tongued debugger

Yeah yeah, it's Rita. The "full" in "full mandate," how far did you read that "full" as going?

No, I get what you mean. If a headline has "full" in it, of course you brace yourself thinking your own old apartment building has to meet the standards starting today. But let me give the answer first. There is no obligation to bring an existing apartment building up to the standards. The obligation switches on when you "build." Only for new construction, and for extensions and reconstruction.

When we read a statute, we pick out the subject and the tense first. The subject of Article 10 of the Building Energy Efficiency Act is "the building owner," and the tense is "when intending to construct a building." Not the person who owns it, but the person who builds it; not while you hold it, but when you are about to build. What became "full" is "the types of buildings to be built from now on": housing and small buildings were all brought in together. It didn't spread to every building that already exists. Get it?

Let's sort it out once. There are 2 assumptions you often hear.

The 1st: "Old properties that don't meet the standards can no longer be rented out or sold." There's no such provision. There is a system for showing energy efficiency performance in rental and sales ads, but that's a duty to make efforts for businesses, and buildings whose building confirmation was applied for before April 2024 aren't required to show it in the set form. The national government does recommend labeling, but not labeling doesn't make you subject to a recommendation.

The 2nd: "If I do a large-scale renovation, I have to meet the standards." Also wrong. Repair and remodeling, even major, are outside the conformity obligation. But if you feel relieved and stop here, you'll step on one thing. For a 2-story wooden apartment building, major repair or remodeling requires building confirmation (smaller wooden buildings were newly brought in by the revision of the Building Standards Act in force from April 2025). The energy efficiency obligation and building confirmation are separate matters. Mix them up, and you get a sloppy plan that checks only one of them.

Now the real point. If you end the story at "there's no obligation," 2 blind spots remain.

The 1st is where the switch sits. For an extension over 10㎡, the added part has to meet the standards. Rebuild, and it's the whole building. Even if it has nothing to do with you now, if you mean to rebuild in 10 years, the construction cost at that time will carry the amount for meeting the standards. The obligation didn't disappear; it's waiting inside a future quote. OK?

The 2nd hits harder. Having no obligation and having no effect are different things. Apartment buildings that start construction from now on will, in principle, come out meeting these standards. They can also be lined up in ads with an energy efficiency label. Next to them, old units whose performance is unknown get lined up. How much of a difference that makes in rent, I don't have numbers I can back up, so I won't say for sure. But it's certain that one more measuring stick for comparison has been added. Am I wrong?

You're right not to panic into "I have to renovate right now." But honestly, knowing nothing and knowing what windows and water heater your own property has give different answers when someone asks. For existing housing, an "energy efficiency component label" showing the components that have had energy efficiency renovations (such as windows and water heaters) also started in November 2024.

There's 1 thing to check. Does your plan include an "extension" or a "rebuild"? If it does, add the amount for meeting the standards to that cost. If it doesn't, the obligation story ends there. What's left is only the story of how you get compared. How about it?

It's La France pear season. Ripeness stickers are put on fruit about to be packed into boxes from now on. Nobody says to stick them afterward on fruit already lined up on the shelf. But, you know, once a box with stickers sits next to it, customers compare. If there's no sticker, pick one up yourself and check the scent.

Read a little deeper